Search
United Arab Emirates (UAE), a prominent GCC member Nation, has an advanced healthcare system. Its market potential is proven and consistently on a rise, governed by the Drug Control Department of the Ministry of Health (DCD MOH). Centralized governance and linguistic barriers are major hinderances for device approvals in the region, along with linguistic complexities and lack of efficient communication channels with the Health Authorities.
Regulatory Authority: Drug Control Department of the Ministry of Health (DCD/MOH)
Regulation: UAE Medical Devices Registration Guideline
Regulatory Pathway: Product Registration
Authorized Representative: Required
QMS Requirement: ISO 13485:2016
Assessment of Technical Data: Medical Device Registration Committee
Validity of License: 5 Years
Labeling Requirements: Annex 2 (2.5) of UAE Medical Devices Registration Guideline
Submission Format: Paper
Language: English
UAE has separate Classification Rules for Medical Devices and IVDs. The classification rules are in line with the classification rules of the EU Medical Device Directives. The class of devices as per the UAE classification rules are as below
Risk Criteria |
Medical Device Class |
Low Risk |
I |
Low Moderate Risk |
IIa |
Moderate – High Risk |
IIb |
High Risk |
III |
Risk Criteria |
IVD Class |
Low Individual Risk and Low Public Health Risk |
A |
Moderate Individual Risk and/or Low Public Health Risk |
B |
High Individual Risk and/or Moderate Public Health Risk |
C |
High Individual Risk and High Public Health Risk |
D |
Foreign Manufacturers, with no physical office shall appoint a Local Representative (LR) to act on behalf of them. The local representative should be licensed by the Ministry of Health as a medical store or scientific office (in case of scientific office, importation and distribution activities should be performed by an appointed Licensed Medical Store). The applicants may appoint their distributor as their Local Representative. However, having an independent Local Representative, with no commercial interest, would provide required flexibility to appoint multiple distributors in the UAE. The details of both the LR and the distributor must be provided during device registration.
Certain Devices do not require prior listing or approval for importation and such devices will be regulated at the time of importation. Such products exempted from registration or listing shall apply and obtain an Import permit to be marketed in UAE.
For other devices, imports will not be cleared unless a pre-approval for importation of the consignment is issued by the DRCD. Such devices shall either be listed or registered to import into the UAE.
Listing of Devices: Generally, products used in hospitals under the professional supervision and Class I devices do not undergo detailed evaluation and they are required to be listed. A Listing Certificate will be issued by the agency. The devices after listing shall obtain import permit to market devices in the UAE.
Registration of Devices: The Registration activity includes Site and Product Registration.
With an exclusive delivery center in Dubai, Freyr holds an authoritative hold on the UAE Medical Device market and outlines the device classification apart from decoding the guidance regulations for better compliance. We support clients in document compilation as per the standards and thus ensure quick approvals. Freyr offers complete range of Regulatory services pertaining to successful device marketing.
Type of Device |
Device Listing |
Device Registration |
Import License |
Device Exempted from Pre-Importation Approval (As listed in Annex 3) |
NA |
NA |
YES |
|
YES |
NA |
YES |
All Other Devices |
NA |
YES |
YES |